TECHNICAL DATA
Operating range: up to 42 to m3/h with head up to 22 m.
Characteristics of pumped liquid: clean water or water slightly contaminated with suspended solid bodies, long fibres;
particularly aggressive water with high percentages of chlorine/bromine and PHMB
(Polyhexamethylene Biguanide) or water treated with chlorine electrolysis process.
PH range: 6.5 – 8.4
Liquid temperature range: up to 60°C
Maximum ambient temperature: 50°C
Maximum working pressure: 2.5 bar
Nominal operating pressure: 0.8 – 1.2 Bar (ideal 1 Bar)
Installation: fixed or portable in horizontal position
Special versions on request: high frequencies and/or voltages
Unions on request: kit 2”/50 – 63 (two unions + O-ring – see “Accessories”)
Reference standard: IEC – 60364
Reviews